<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>DGN Plus - Turkiye'nin Teknoloji Merkezi Yukseliyor. Bursa Datacenter, Veri merkezi &#187; Datacenter</title>
	<atom:link href="http://www.dgnplus.com/category/datacenter/feed" rel="self" type="application/rss+xml" />
	<link>http://www.dgnplus.com</link>
	<description>DGN Plus - Turkiye'nin Teknoloji Merkezi Yukseliyor. Bursa Datacenter, Veri merkezi</description>
	<lastBuildDate>Fri, 11 Dec 2009 09:08:06 +0000</lastBuildDate>
	<generator>http://wordpress.org/?v=2.9.2</generator>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
			<item>
		<title>Network Kablolama</title>
		<link>http://www.dgnplus.com/2009-10-14-network-kablolama.htm</link>
		<comments>http://www.dgnplus.com/2009-10-14-network-kablolama.htm#comments</comments>
		<pubDate>Wed, 14 Oct 2009 08:44:46 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Datacenter]]></category>
		<category><![CDATA[cat6]]></category>
		<category><![CDATA[Halogen Free]]></category>
		<category><![CDATA[hf]]></category>
		<category><![CDATA[network kablolama]]></category>
		<category><![CDATA[Unshielded Twisted Pair]]></category>
		<category><![CDATA[UTP]]></category>

		<guid isPermaLink="false">http://www.dgnplus.com/?p=228</guid>
		<description><![CDATA[
Yüksek hız ve performans için tüm iç network kablolamasında Cat6 UTP (Unshielded Twisted Pair) HF (Halogen Free) kablolar kullanılmaktadır. Proje dahilinde yükseltilmiş döşeme altında bulunan kablo tavalarına yerleştirilen network kabloları bina enerji altyapısında olduğu gibi HF özellikli seçilmiş olup, bu tercih ile oluşabilecek bir yangın durumunda kablo kaynaklı zehirli gaz çıkışı engellenmiştir.

	Tags: cat6, Halogen Free, [...]]]></description>
			<content:encoded><![CDATA[<p><center><img alt="" src="http://www.dgnplus.com/resim/datacenter-utp-hf.jpg" title="UTP HF Cable" class="alignnone" width="450" height="338" /></center><br />
Yüksek hız ve performans için tüm iç network kablolamasında Cat6 UTP (Unshielded Twisted Pair) HF (Halogen Free) kablolar kullanılmaktadır. Proje dahilinde yükseltilmiş döşeme altında bulunan kablo tavalarına yerleştirilen network kabloları bina enerji altyapısında olduğu gibi HF özellikli seçilmiş olup, bu tercih ile oluşabilecek bir yangın durumunda kablo kaynaklı zehirli gaz çıkışı engellenmiştir.</p>

	Tags: <a href="http://www.dgnplus.com/tag/cat6" title="cat6" rel="tag">cat6</a>, <a href="http://www.dgnplus.com/tag/halogen-free" title="Halogen Free" rel="tag">Halogen Free</a>, <a href="http://www.dgnplus.com/tag/hf" title="hf" rel="tag">hf</a>, <a href="http://www.dgnplus.com/tag/network-kablolama" title="network kablolama" rel="tag">network kablolama</a>, <a href="http://www.dgnplus.com/tag/unshielded-twisted-pair" title="Unshielded Twisted Pair" rel="tag">Unshielded Twisted Pair</a>, <a href="http://www.dgnplus.com/tag/utp" title="UTP" rel="tag">UTP</a><br />

	<h4>Related posts</h4>
	<ul class="st-related-posts">
	<li>No related posts.</li>
	</ul>

]]></content:encoded>
			<wfw:commentRss>http://www.dgnplus.com/2009-10-14-network-kablolama.htm/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>DGN Teknoloji Datacenter</title>
		<link>http://www.dgnplus.com/2009-10-06-dgn-teknoloji-datacenter.htm</link>
		<comments>http://www.dgnplus.com/2009-10-06-dgn-teknoloji-datacenter.htm#comments</comments>
		<pubDate>Tue, 06 Oct 2009 10:29:04 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Datacenter]]></category>
		<category><![CDATA[atx]]></category>
		<category><![CDATA[datacenter mimari]]></category>
		<category><![CDATA[datacenter resim]]></category>
		<category><![CDATA[güvenlik]]></category>
		<category><![CDATA[güvenlik kamerası]]></category>
		<category><![CDATA[kartlı geçiş sistemi]]></category>
		<category><![CDATA[rack kabin]]></category>
		<category><![CDATA[raf]]></category>
		<category><![CDATA[turnike]]></category>

		<guid isPermaLink="false">http://www.dgnplus.com/?p=214</guid>
		<description><![CDATA[
Proje için özel tasarlanan ilk kabin grubu, ATX serverların yerleştirileceği raf sistemi ve tamamı proje kapsamında ithal edilen Juniper marka network cihazlarınında ulaşması sonrasında datacenter fiziksel yerleşim büyük ölçüde tamamlanmış oldu. 
Bina genelinde karşılama turnikesi ile başlayarak, depolar, ofisler, NOC ve datacenter gibi bölümlere girişi sağlayan kartlı geçiş sistemi ile güvenlik en üst seviyede tutulurken [...]]]></description>
			<content:encoded><![CDATA[<p><center><img alt="" src="http://www.dgnplus.com/resim/datacenter-ve-guvenlik.jpg" title="DGN Teknoloji Datacenter" class="alignnone" width="450" height="324" /></center><br />
Proje için özel tasarlanan ilk kabin grubu, ATX serverların yerleştirileceği raf sistemi ve tamamı proje kapsamında ithal edilen Juniper marka network cihazlarınında ulaşması sonrasında datacenter fiziksel yerleşim büyük ölçüde tamamlanmış oldu. </p>
<p>Bina genelinde karşılama turnikesi ile başlayarak, depolar, ofisler, NOC ve datacenter gibi bölümlere girişi sağlayan kartlı geçiş sistemi ile güvenlik en üst seviyede tutulurken bina genelinde önemli her noktaya yerleştirilen güvenlik kameraları ilede giriş çıkışlar kontrol altında tutulmaktadır.</p>
<p><center><img alt="" src="http://www.dgnplus.com/resim/giris-kamera.jpg" title="Giriş Kamera" class="alignnone" width="450" height="350" /></center></p>
<p>Hot Swap enerji altyapısı ile istenildiği zaman eklenip çıkartılabilen kabin ve raf enerji besleme sistemi sayesinde serverlara ulaşacak enerji kabloları sorunsuz olarak tamamlanarak network kablolama işlemi başlatıldı. </p>

	Tags: <a href="http://www.dgnplus.com/tag/atx" title="atx" rel="tag">atx</a>, <a href="http://www.dgnplus.com/tag/datacenter" title="Datacenter" rel="tag">Datacenter</a>, <a href="http://www.dgnplus.com/tag/datacenter-mimari" title="datacenter mimari" rel="tag">datacenter mimari</a>, <a href="http://www.dgnplus.com/tag/datacenter-resim" title="datacenter resim" rel="tag">datacenter resim</a>, <a href="http://www.dgnplus.com/tag/guvenlik" title="güvenlik" rel="tag">güvenlik</a>, <a href="http://www.dgnplus.com/tag/guvenlik-kamerasi" title="güvenlik kamerası" rel="tag">güvenlik kamerası</a>, <a href="http://www.dgnplus.com/tag/kartli-gecis-sistemi" title="kartlı geçiş sistemi" rel="tag">kartlı geçiş sistemi</a>, <a href="http://www.dgnplus.com/tag/rack-kabin" title="rack kabin" rel="tag">rack kabin</a>, <a href="http://www.dgnplus.com/tag/raf" title="raf" rel="tag">raf</a>, <a href="http://www.dgnplus.com/tag/turnike" title="turnike" rel="tag">turnike</a><br />

	<h4>Related posts</h4>
	<ul class="st-related-posts">
	<li><a href="http://www.dgnplus.com/2009-10-06-enerji-sistemi.htm" title="Enerji Sistemi (06 Ekim 2009)">Enerji Sistemi</a> (0)</li>
	<li><a href="http://www.dgnplus.com/2009-06-15-datacenterdan-ilk-kareler.htm" title="Datacenter&#8217;dan ilk kareler (15 Haziran 2009)">Datacenter&#8217;dan ilk kareler</a> (0)</li>
	<li><a href="http://www.dgnplus.com/2008-02-25-tasarim-masasi.htm" title="Tasarım masası (25 Şubat 2008)">Tasarım masası</a> (0)</li>
	<li><a href="http://www.dgnplus.com/2009-08-02-hassas-klima.htm" title="Hassas Sıcaklık ve Nem Kontrolü (02 Ağustos 2009)">Hassas Sıcaklık ve Nem Kontrolü</a> (1)</li>
	<li><a href="http://www.dgnplus.com/2009-07-03-fm-200.htm" title="FM-200 Gazlı yangın söndürme (03 Temmuz 2009)">FM-200 Gazlı yangın söndürme</a> (3)</li>
</ul>

]]></content:encoded>
			<wfw:commentRss>http://www.dgnplus.com/2009-10-06-dgn-teknoloji-datacenter.htm/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Hassas Sıcaklık ve Nem Kontrolü</title>
		<link>http://www.dgnplus.com/2009-08-02-hassas-klima.htm</link>
		<comments>http://www.dgnplus.com/2009-08-02-hassas-klima.htm#comments</comments>
		<pubDate>Sun, 02 Aug 2009 16:49:19 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Datacenter]]></category>
		<category><![CDATA[datacenter soğutma]]></category>
		<category><![CDATA[Hassas Sıcaklık Nem Kontrolü]]></category>
		<category><![CDATA[iklimlendirme]]></category>
		<category><![CDATA[klima]]></category>
		<category><![CDATA[nem]]></category>
		<category><![CDATA[proje]]></category>
		<category><![CDATA[statik elektrik]]></category>
		<category><![CDATA[verimli]]></category>

		<guid isPermaLink="false">http://www.dgnplus.com/?p=194</guid>
		<description><![CDATA[Datacenter ortamında bulunan donanımların verimli bir şekilde çalışabilmesi için de ortamda belli bir iklim şartının sabit tutulabilmesi gerekmektedir. Bu ihtiyacın sonucu olarak da hassas sıcaklık ve nem kontrollü klimalar gün geçtikçe bilişim sektörünün vazgeçilmez bir parçası halini almıştır.

Network cihazları ve serverların verimli çalışabilmesi için %50 nem oranı sabit oranda tutulmalıdır. Düşük nem oranında oluşan ortam [...]]]></description>
			<content:encoded><![CDATA[<p>Datacenter ortamında bulunan donanımların verimli bir şekilde çalışabilmesi için de ortamda belli bir iklim şartının sabit tutulabilmesi gerekmektedir. Bu ihtiyacın sonucu olarak da hassas sıcaklık ve nem kontrollü klimalar gün geçtikçe bilişim sektörünün vazgeçilmez bir parçası halini almıştır.</p>
<p style="text-align: center;"><img class="aligncenter" title="Hassas Kontrollü Klima Sistemi Dış Ünite" src="http://www.dgnplus.com/resim/hassas-klima-rc.jpg" alt="" width="450" height="353" /></p>
<p>Network cihazları ve serverların verimli çalışabilmesi için %50 nem oranı sabit oranda tutulmalıdır. Düşük nem oranında oluşan ortam statik elektrik iletimini arttırmakta yüksek nem oranı ise cihazlarda oksitlenmeye bağlı hasarlar oluşturmaktadır.</p>
<p>Bunun yanında dış ortamdan alınacak havanın datacenter içinde dolaştırılması ile yapılacak soğutma dışarıdan gelebilecek partiküllerin tamamının filtrelenmesi zor olduğundan ve nem dengesini bozduğundan ideal bir sistem olamamaktadır. Yine insan kullanımı için tasarlanan soğutma sistemleri (klimalar) ile datacenter soğutması istenilen sonuçlar alınamamaktadır.</p>
<p style="text-align: center;"><img class="aligncenter" title="Hassas Kontrollü Klima Sistemi" src="http://www.dgnplus.com/resim/hassas-klima-rc-2.jpg" alt="" width="450" height="394" /></p>
<p>Bu nedenle<strong> DGN Plus </strong>Projesinde yer alan datacenter dünyadaki tüm büyük verimerkezleri gibi hassas kontrollü klima sistemleri ile donatılmış durumdadır. Toplam 800 Kwatt soğutma kapasitesi hedeflenen datacenterda yer alan iklimlendirme sistemine ait 1 ton ağırlığındaki ilk iç ünite datacenter içine konumlandırılmış olup, iç ünite ile bağlantısı sağlanan dış ünite ile iklimlendirme sistemi montajı tamamlanmıştır.</p>

	Tags: <a href="http://www.dgnplus.com/tag/datacenter" title="Datacenter" rel="tag">Datacenter</a>, <a href="http://www.dgnplus.com/tag/datacenter-sogutma" title="datacenter soğutma" rel="tag">datacenter soğutma</a>, <a href="http://www.dgnplus.com/tag/hassas-sicaklik-nem-kontrolu" title="Hassas Sıcaklık Nem Kontrolü" rel="tag">Hassas Sıcaklık Nem Kontrolü</a>, <a href="http://www.dgnplus.com/tag/iklimlendirme" title="iklimlendirme" rel="tag">iklimlendirme</a>, <a href="http://www.dgnplus.com/tag/klima" title="klima" rel="tag">klima</a>, <a href="http://www.dgnplus.com/tag/nem" title="nem" rel="tag">nem</a>, <a href="http://www.dgnplus.com/tag/proje" title="proje" rel="tag">proje</a>, <a href="http://www.dgnplus.com/tag/statik-elektrik" title="statik elektrik" rel="tag">statik elektrik</a>, <a href="http://www.dgnplus.com/tag/verimli" title="verimli" rel="tag">verimli</a><br />

	<h4>Related posts</h4>
	<ul class="st-related-posts">
	<li><a href="http://www.dgnplus.com/2008-02-25-tasarim-masasi.htm" title="Tasarım masası (25 Şubat 2008)">Tasarım masası</a> (0)</li>
	<li><a href="http://www.dgnplus.com/2009-07-03-fm-200.htm" title="FM-200 Gazlı yangın söndürme (03 Temmuz 2009)">FM-200 Gazlı yangın söndürme</a> (3)</li>
	<li><a href="http://www.dgnplus.com/2008-05-14-topraklama.htm" title="Topraklama (14 Mayıs 2008)">Topraklama</a> (1)</li>
	<li><a href="http://www.dgnplus.com/2009-10-06-enerji-sistemi.htm" title="Enerji Sistemi (06 Ekim 2009)">Enerji Sistemi</a> (0)</li>
	<li><a href="http://www.dgnplus.com/2009-10-06-dgn-teknoloji-datacenter.htm" title="DGN Teknoloji Datacenter (06 Ekim 2009)">DGN Teknoloji Datacenter</a> (0)</li>
</ul>

]]></content:encoded>
			<wfw:commentRss>http://www.dgnplus.com/2009-08-02-hassas-klima.htm/feed</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
		<item>
		<title>Yükseltilmiş Döşeme (Raised Floor)</title>
		<link>http://www.dgnplus.com/2009-07-14-yukseltilmis-doseme-raised-floor.htm</link>
		<comments>http://www.dgnplus.com/2009-07-14-yukseltilmis-doseme-raised-floor.htm#comments</comments>
		<pubDate>Tue, 14 Jul 2009 17:07:10 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Datacenter]]></category>
		<category><![CDATA[anti statik lamine]]></category>
		<category><![CDATA[galvanize çelik]]></category>
		<category><![CDATA[raised floor]]></category>
		<category><![CDATA[yükseltilmiş döşeme]]></category>

		<guid isPermaLink="false">http://www.dgnplus.com/?p=184</guid>
		<description><![CDATA[
Yükseltilmiş Döşeme Sistemleri günümüz modern yapılaşmasında bilgi işlem merkezlerinde (datacenter) flexible kullanım, tasarım olanağı ve teknik ihtiyaçlara fonksiyonelliği ile cevap veren bir sistemdir. İdeal datacenter alanlarında soğutma sistemlerinin verimli çalışabilmesi için gerek duyulan yükseltilmiş döşeme sistemi özel olarak hazırlanan ayaklar ve kuşak sistemi üzerine kurulmakta ve döşeme malzemesi olarak sunta özlü paneller yüksek yangın dayanımı [...]]]></description>
			<content:encoded><![CDATA[<p><img class="aligncenter" title="Raised Floor - Yükseltilmiş döşeme" src="http://www.dgnplus.com/resim/raised-floor-yukseltilmis.jpg" alt="" width="450" height="518" /></p>
<p>Yükseltilmiş Döşeme Sistemleri günümüz modern yapılaşmasında bilgi işlem merkezlerinde (datacenter) flexible kullanım, tasarım olanağı ve teknik ihtiyaçlara fonksiyonelliği ile cevap veren bir sistemdir. İdeal datacenter alanlarında soğutma sistemlerinin verimli çalışabilmesi için gerek duyulan yükseltilmiş döşeme sistemi özel olarak hazırlanan ayaklar ve kuşak sistemi üzerine kurulmakta ve döşeme malzemesi olarak sunta özlü paneller yüksek yangın dayanımı ve ses yutma özelliklerine sahiptir.</p>
<p style="text-align: center;"><img class="aligncenter" title="Raised Floor - Yükseltilmiş döşeme - Hassas klima" src="http://www.dgnplus.com/resim/raised-floor-ac.jpg" alt="" width="450" height="248" /></p>
<p><strong>DGN Plus</strong> datacenter projesinde yüksek dayanımı sağlamak amacı ile kullanılan panellerin üst kısmı anti statik lamine alt kısmı ise galvanize çeliktir. Yine sistem bütününde oluşacak statik elektriği sorunsuz şekilde aktarmak için kurulan ayaklara topraklama hattı bağlantısı sağlanmıştır.</p>
<p>Proje dahilinde kullanılan panellerin özellikleri aşağıdaki şekildedir.</p>
<p>Panel Ağırlığı  : 8,5 Kg/ Panel<br />
Panel Özü  :Yüksek Yoğunluklu Yonga Levha  </p>
<p>Çalışma Yükü  : 3,23kN<br />
Maksimum Yük  : 9,7kN  </p>

	Tags: <a href="http://www.dgnplus.com/tag/anti-statik-lamine" title="anti statik lamine" rel="tag">anti statik lamine</a>, <a href="http://www.dgnplus.com/tag/galvanize-celik" title="galvanize çelik" rel="tag">galvanize çelik</a>, <a href="http://www.dgnplus.com/tag/raised-floor" title="raised floor" rel="tag">raised floor</a>, <a href="http://www.dgnplus.com/tag/yukseltilmis-doseme" title="yükseltilmiş döşeme" rel="tag">yükseltilmiş döşeme</a><br />

	<h4>Related posts</h4>
	<ul class="st-related-posts">
	<li><a href="http://www.dgnplus.com/2009-07-12-calismalar-devam-ediyor.htm" title="Çalışmalar devam ediyor (12 Temmuz 2009)">Çalışmalar devam ediyor</a> (0)</li>
</ul>

]]></content:encoded>
			<wfw:commentRss>http://www.dgnplus.com/2009-07-14-yukseltilmis-doseme-raised-floor.htm/feed</wfw:commentRss>
		<slash:comments>3</slash:comments>
		</item>
		<item>
		<title>FM-200 Gazlı yangın söndürme</title>
		<link>http://www.dgnplus.com/2009-07-03-fm-200.htm</link>
		<comments>http://www.dgnplus.com/2009-07-03-fm-200.htm#comments</comments>
		<pubDate>Fri, 03 Jul 2009 17:46:06 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Datacenter]]></category>
		<category><![CDATA[fm-200]]></category>
		<category><![CDATA[Heptafluoropropane]]></category>
		<category><![CDATA[HFC 227]]></category>
		<category><![CDATA[nozul]]></category>
		<category><![CDATA[proje]]></category>
		<category><![CDATA[yangın söndürme sistemi]]></category>

		<guid isPermaLink="false">http://www.dgnplus.com/?p=162</guid>
		<description><![CDATA[Datacenterlarda oluşabilecek herhangi bir yangın durumunda bilindik olağan söndürme yöntemleri (suyla veya kuru toz içeren yangın tüpleriyle) hesaplanması mümkün olmayan hasarlar oluşturabilmektedir.
Gerçekleşebilecek bir yangının en hızlı ve sistemlere zarar vermeden söndürmenin en etkin yolu kurallara uygun projelendirilerek, tesis edilmiş bir FM-200 gazlı söndürme sistemidir. DGN Plus&#8216;un her aşamasında uygulanan son teknolojik gelişmeler yangın güvenliği konusunda [...]]]></description>
			<content:encoded><![CDATA[<p>Datacenterlarda oluşabilecek herhangi bir yangın durumunda bilindik olağan söndürme yöntemleri (suyla veya kuru toz içeren yangın tüpleriyle) hesaplanması mümkün olmayan hasarlar oluşturabilmektedir.</p>
<p>Gerçekleşebilecek bir yangının en hızlı ve sistemlere zarar vermeden söndürmenin en etkin yolu kurallara uygun projelendirilerek, tesis edilmiş bir FM-200 gazlı söndürme sistemidir. <strong>DGN Plus</strong>&#8216;un her aşamasında uygulanan son teknolojik gelişmeler yangın güvenliği konusunda da dünyanın tercih ettiği alternatifsiz yöntemle çözülmüştür.</p>
<p style="text-align: center;"><img class="aligncenter" title="Fm-200 Yangın Söndürme Sistemi" src="http://dgnplus.com/resim/fm-200-yangin-sondurme.jpg" alt="" width="450" height="179" /></p>
<p>FM-200 gazının kullanıldığı sistemlerinin defalarca test ve denemeleri yapılmış ve en etkili, en temiz, insan hayatı için en güvenli, çevre için (ozon tabakası) hiçbir zararı olmayan bir sistem olduğu belirlenmiştir.</p>
<p>Kimyasal formülü HFC 227 ile belirlenen FM-200 gazı, Heptafluoropropane olarak isimlendirilir.FM-200 gazı renksiz ve kokusuz bir gazdır. Halon’a benzer olarak 25 bar basınç altında tüplere doldurularak sıvı halde depolanabilir. Uygulanabilir ve kullanılabilir olmasındaki en önemli nokta sıvı durumdaki gazın, püskürtme nozulları yoluyla serbest bırakılması sonucu buharlaşarak korunacak hacimde yanıcı yüzey üzerinde bir tabaka oluşturarak yanmayı önlemesidir. Halon gazının söndürme özelliği kimyasal olmasına karşın, FM-200 gazının söndürme özelliği fizikseldir.</p>
<p style="text-align: center;"><img src="" /></p>

	Tags: <a href="http://www.dgnplus.com/tag/datacenter" title="Datacenter" rel="tag">Datacenter</a>, <a href="http://www.dgnplus.com/tag/fm-200" title="fm-200" rel="tag">fm-200</a>, <a href="http://www.dgnplus.com/tag/heptafluoropropane" title="Heptafluoropropane" rel="tag">Heptafluoropropane</a>, <a href="http://www.dgnplus.com/tag/hfc-227" title="HFC 227" rel="tag">HFC 227</a>, <a href="http://www.dgnplus.com/tag/nozul" title="nozul" rel="tag">nozul</a>, <a href="http://www.dgnplus.com/tag/proje" title="proje" rel="tag">proje</a>, <a href="http://www.dgnplus.com/tag/yangin-sondurme-sistemi" title="yangın söndürme sistemi" rel="tag">yangın söndürme sistemi</a><br />

	<h4>Related posts</h4>
	<ul class="st-related-posts">
	<li><a href="http://www.dgnplus.com/2008-02-25-tasarim-masasi.htm" title="Tasarım masası (25 Şubat 2008)">Tasarım masası</a> (0)</li>
	<li><a href="http://www.dgnplus.com/2009-08-02-hassas-klima.htm" title="Hassas Sıcaklık ve Nem Kontrolü (02 Ağustos 2009)">Hassas Sıcaklık ve Nem Kontrolü</a> (1)</li>
	<li><a href="http://www.dgnplus.com/2009-10-06-enerji-sistemi.htm" title="Enerji Sistemi (06 Ekim 2009)">Enerji Sistemi</a> (0)</li>
	<li><a href="http://www.dgnplus.com/2009-10-06-dgn-teknoloji-datacenter.htm" title="DGN Teknoloji Datacenter (06 Ekim 2009)">DGN Teknoloji Datacenter</a> (0)</li>
	<li><a href="http://www.dgnplus.com/2009-07-12-calismalar-devam-ediyor.htm" title="Çalışmalar devam ediyor (12 Temmuz 2009)">Çalışmalar devam ediyor</a> (0)</li>
</ul>

]]></content:encoded>
			<wfw:commentRss>http://www.dgnplus.com/2009-07-03-fm-200.htm/feed</wfw:commentRss>
		<slash:comments>3</slash:comments>
		</item>
		<item>
		<title>Datacenter&#8217;dan ilk kareler</title>
		<link>http://www.dgnplus.com/2009-06-15-datacenterdan-ilk-kareler.htm</link>
		<comments>http://www.dgnplus.com/2009-06-15-datacenterdan-ilk-kareler.htm#comments</comments>
		<pubDate>Sun, 14 Jun 2009 23:46:35 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Datacenter]]></category>
		<category><![CDATA[alçı sıva]]></category>
		<category><![CDATA[datacenter mimari]]></category>
		<category><![CDATA[datacenter resim]]></category>
		<category><![CDATA[veri merkezi fotoğrafları]]></category>

		<guid isPermaLink="false">http://www.dgnplus.com/?p=155</guid>
		<description><![CDATA[
DGN Plus bina projesinin her katında yoğun çalışmalar devam ederken enerji ve network altyapısından, soğutma sistemlerine kadar en ince ayrıntısına kadar konunun ehli mühendis kadrosu tarafından projelendirişmiş datacenter (veri merkezi) ait ilk fotoğrafı eklemekten büyük mutluluk duymaktayız.

	Tags: alçı sıva, datacenter mimari, datacenter resim, veri merkezi fotoğrafları

	Related posts
	
	DGN Teknoloji Datacenter (0)
	DGN Plus&#8217;a Taşındık. (1)


]]></description>
			<content:encoded><![CDATA[<p style="text-align: center;"><img class="aligncenter" title="Alçı sıva" src="http://www.dgnplus.com/resim/datacenter-alci-siva.jpg" alt="" width="450" height="321" /></p>
<p><strong>DGN Plus</strong> bina projesinin her katında yoğun çalışmalar devam ederken enerji ve network altyapısından, soğutma sistemlerine kadar en ince ayrıntısına kadar konunun ehli mühendis kadrosu tarafından projelendirişmiş datacenter (veri merkezi) ait ilk fotoğrafı eklemekten büyük mutluluk duymaktayız.</p>

	Tags: <a href="http://www.dgnplus.com/tag/alci-siva" title="alçı sıva" rel="tag">alçı sıva</a>, <a href="http://www.dgnplus.com/tag/datacenter-mimari" title="datacenter mimari" rel="tag">datacenter mimari</a>, <a href="http://www.dgnplus.com/tag/datacenter-resim" title="datacenter resim" rel="tag">datacenter resim</a>, <a href="http://www.dgnplus.com/tag/veri-merkezi-fotograflari" title="veri merkezi fotoğrafları" rel="tag">veri merkezi fotoğrafları</a><br />

	<h4>Related posts</h4>
	<ul class="st-related-posts">
	<li><a href="http://www.dgnplus.com/2009-10-06-dgn-teknoloji-datacenter.htm" title="DGN Teknoloji Datacenter (06 Ekim 2009)">DGN Teknoloji Datacenter</a> (0)</li>
	<li><a href="http://www.dgnplus.com/2009-11-04-dgn-plusa-tasindik.htm" title="DGN Plus&#8217;a Taşındık. (04 Kasım 2009)">DGN Plus&#8217;a Taşındık.</a> (1)</li>
</ul>

]]></content:encoded>
			<wfw:commentRss>http://www.dgnplus.com/2009-06-15-datacenterdan-ilk-kareler.htm/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
